• Childers Knudsen posted an update 4 hours, 19 minutes ago

    The model, based on an empirical description of two-component, competitive isotherms at low sodium phosphate concentration coupled with the stoichiometric displacement model at higher sodium phosphate concentrations, is in good agreement with the experiments using the linear driving force (LDF) approximation to describe adsorption/desorption kinetics. The same LDF rate coefficient predicts the separation at loadings between 0.8 and 30 mg/mL. The model developed in this work can be used as a general tool to optimize operating conditions, understand what factors limit performance, and compare different operating modes.A novel protein-based gel named “Yu dong” prepared with fish (Cyprinus carpio L.) scale aqueous extract and enhanced by polysaccharides is described in this study. The effects of pectin, alginate, and sodium carboxyl methyl cellulose (CMC-Na) on FS gel formation, stability, textural characteristics, microstructure, and water distribution were evaluated. The results indicated the viscosity of the FS gels decreased and changed slowly as the addition of pectin. While, the addition of alginate enhanced the formation of FS gels. As pectin addition in FS gels, the transition temperature decreased. When alginate and CMC-Na was added to the FS gels, the transition temperature increased. The addition of pectin, alginate, and CMC-Na to the FS gels significantly increased Gr from 44.5% to 71.99%, 61.86%, and 71.35%, respectively. Gel strength increased significantly as the addition of pectin, alginate, and CMC-Na. LF-NMR results showed that a moderate amount (0.2%) of polysaccharides bonded the protein and water more tightly, which was consistent with the SEM results showing gel structure with more uniform pores. This study provides a direct application of FS protein in preparing of gel food, which showing a better way to utilize the abandoned fish resource.A rapid colorimetric method using cysteine-modified silver nanoparticles (Cys-AgNPs) is applied for the detection of 3-monochloropropane-1,2-diol (3-MCPD). Indeed, in the presence of 3-MCPD, the color of Cys-AgNPs solution changes from yellow to pink within five minutes at 100 °C and pH 9.3. This change is mainly attributed to the ability of amino group of cysteine to react with 3-MCPD to form N-(2,3-dihydroxypropyl)-amino acid grafted on AgNPs (3-MCPD-Cys-AgNPs) in alkaline medium. This color change makes 3-MCPD to be clearly detectable by unassisted visual means even at 0.1 μg⋅mL-1. Besides, using UV-Vis spectroscopic technique, a linear range from 0.1 μg⋅mL-1 to 1.25 μg⋅mL-1 for 3-MCPD detection is obtained, with a calculated detection limit of 0.084 μg⋅mL-1. These results suggest that this sensing technique is sensitive to 3-MCPD and may have a substantial application in the rapid detection of food contaminants particularly, where quality and safety of food products are paramount concern.In this study, roasting was applied to enhance the volatile compound content and antioxidant activity of hot-air dried omija (Schisandra chinensis Baillon) fruit. The major volatile compounds were furfural, 1,8-cineole and terpinen-4-ol. Total volatile compound concentration in omija roasted at 150 ℃ for 15 min was approximately 4 times higher than that in hot-air dried omija. Contents of monoterpenes and sesquiterpenes in roasted omija were significantly increased, compared to that of the hot-air dried omija (P less then 0.05). The contents of schizandrin in extracts of hot-air dried omija and omija roasted at 150 ℃ for 10 min were determined to be 28.9 and 106.5 mg/100 g extract, respectively. The content of gomisin A from roasted omija was about 5 times higher than that of hot-air dried omija. Through this study, it is believed that the usability of omija will be expanded.Lactoferrin (LF), a bioactive multifunctional protein of the transferrin family, is found mainly in the secretions of all mammals, especially in milk. In the present study, a hybridoma cell (LF8) secreting IgG against bovine LF was screened, and the purified LF8 mAb showed high specificity and affinity to bovine LF. The linear range of ic-ELISA to detect LF was 9.76 ~ 625 ng/mL, with a limit of detection (LOD) of 0.01 ng/mL. The average recovery of intra- and inter-assay were (104.45 ± 4.12)% and (107.13 ± 4.72)%, respectively. The LOD of colloidal gold- and AuNFs-based strip by naked eye were 9.7 and 2.4 ng/mL, respectively, and the detection time was less than 10 min without any samples pretreatment and expensive equipment. The developed ELISA and lateral flow immunosensors based on specific IgG could be used directly for rapid detection of the bovine LF content in cow milk samples.

    We evaluated a rapid chromatographic immunoassay (IgG/IgM antibodies) and an ELISA assay to diagnose COVID-19 in patient sat two Brazilian hospitals.

    A total of 122 subjects with COVID-19 were included 106 SARS-COV-2 RT-PCR-positive patients and 16 RT-PCR-negative patients with symptoms and chest computed tomography (CT) consistent with COVID-19. Ninety-six historical blood donation samples were used as controls. Demographic and clinical characteristics were retrieved from electronic records. Sensitivity and specificity were calculated, as were their 95% binomial confidence intervals using the Clopper-Pearson method. All analyses were performed in R version 3.6.3.

    The sensitivity of the chromatographic immunoassay in all RT-PCR-positive patients, irrespective of the timing of symptom onset, was 85.8% (95% binomial CI 77.7% to 91.9%). This increased with time after symptom onset, and at >14 days was 94.9% (85.9% to 98.9%). The specificity was 100% (96.4% to 100%). 15/16 (94%) RT- PCR-negative cases tested positive. The most frequent comorbidities were hypertension and diabetes mellitus and the most frequent symptoms were fever, cough, and dyspnea. buy Chlorin e6 All RT-PCR-negative patients had pneumonia. The most frequent thoracic CT findings were ground glass changes (n = 11, 68%), which were bilateral in 9 (56%) patients, and diffuse reticulonodular infiltrates (n = 5, 31%).

    The COVID-19 rapid chromatographic immunoassay evaluated in this study had a high sensitivity and specificity using plasma, particularly after 14 days from symptom onset. ELISA and qualitative rapid chromatographic immunoassays can be used for the diagnosis of RT-PCR-negative patients.

    The COVID-19 rapid chromatographic immunoassay evaluated in this study had a high sensitivity and specificity using plasma, particularly after 14 days from symptom onset. ELISA and qualitative rapid chromatographic immunoassays can be used for the diagnosis of RT-PCR-negative patients.